red-noiseMemberQuote:Does anyone know about powering a 7.5 V powered pedal (Hum Debugger) with a 9V pedal board power jack?
Answering an old quote to benefit anybody searching with the same question now or in the future
The main issue here isn’t 7.5v versus 9v, but rather AC versus DC. The Hum Debugger runs off AC while pedal board power is DC. Mix the two and you will be shopping for a new Hum Debugger.
red-noiseMemberI imagine that would have increased the price considerably, and surely EHX wasn’t expecting to issue a bunch of updates over the years. I don’t see this as being a big problem actually because the price point was really sweet when it first came out. (But now the SQ1 from Korg is hard to compete against…)
November 25, 2015 at 11:02 pm in reply to: 8 Step Program timing problem (v3) > Internal clock #121036red-noiseMemberI’m in Chicago / USA … It’s out of warranty; does that matter for a firmware update?
November 25, 2015 at 7:01 pm in reply to: 8 Step Program timing problem (v3) > Internal clock #121031red-noiseMemberQuote:It’s possible this is a defective unit or maybe just needs the firmware to be re-flashed. What are you using to power the 8 Step?I’m powering it with the original PSU that it came with. Re-flashing the firmware sounds like it’s worth a shot! What would be involved in doing that? Can that be done over MIDI / SYSEX?
thanks,
– ScottNovember 24, 2015 at 3:29 pm in reply to: 8 Step Program timing problem (v3) > Internal clock #121016red-noiseMemberAnybody?? Nobody?? I would love to resolve the timing issue on this…
-